IWB_WDOMAINR<n>, n = 0 - 4095
IWB Wire Interrupt Domain Selection Register
IWB Wire Interrupt Domain Selection Register. Allows software to configure the Interrupt Domain that wires n 16 through ((n 16) + 15) are assigned to.
Configuration
This register is present only when FEAT_GICv5_EXT is implemented. Otherwise, direct accesses to IWB_WDOMAINR<n> are RES0.
The number of implemented IWB_WDOMAINR<n> registers is (IWB_IDR0.IW_RANGE + 1) * 2.
The effects of a write to this register are not guaranteed to have completed until IWB_WDOMAIN_STATUSR.IDLE is 1.
Attributes
IWB_WDOMAINR<n> is a 32-bit register.
This register is part of the IWB_CONFIG_FRAME block.
Field descriptions
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WDOM15 | WDOM14 | WDOM13 | WDOM12 | WDOM11 | WDOM10 | WDOM9 | WDOM8 | WDOM7 | WDOM6 | WDOM5 | WDOM4 | WDOM3 | WDOM2 | WDOM1 | WDOM0 | ||||||||||||||||
WDOM<x>, bits [2x+1:2x], for x = 15 to 0:
Configures the Interrupt Domain that wire ((16 * n) + x) is assigned to.
Programming an Interrupt Domain not supported by the IWB results in CONSTRAINED UNPREDICTABLE behavior with the following options:
- No signals are generated by the IWB for a wire assigned to an unsupported Interrupt Domain.
- The wire is treated as being assigned to another supported Interrupt Domain and a read of this field returns the Interrupt Domain the wire is assigned to.
Access to control fields for wires which are not implemented are RAZ/WI.
| WDOM<x> | Meaning |
|---|---|
| 0b00 |
Secure |
| 0b01 |
Non-secure |
| 0b10 |
EL3 |
| 0b11 |
Realm |
The reset behavior of this field is:
- On a GIC reset, this field resets to an UNKNOWN value.
Accessing this field has the following behavior:
- When IsWireDomainRO((n * 16) + x), access to this field is RO.
- Otherwise, access to this field is RW.
Access Instructions
When the Interrupt Domain assigned of a wire is fixed, access to the corresponding field is RO.
This register can only be accessed through the MPPAS of the IWB.
Accesses to this register use the following encodings:
Accessible at offset 0x8000 + (4 * n) from IWB_CONFIG_FRAME
- When IWB_CR0.IDLE == '0', accesses to this register are RO.
- When !IsAccessIWBMPPAS(), accesses to this register are RAZ/WI.
- Otherwise, accesses to this register are RW.
()