ITS_SWERR_SYNDROMER0
ITS Software Error Syndrome Register 0
ITS Software Error Syndrome Register 0. Records ITS specific software error syndrome information.
Configuration
This register is present only when FEAT_GICv5_EXT is implemented and ITS_IDR0.SWE == '1'. Otherwise, direct accesses to ITS_SWERR_SYNDROMER0 are RES0.
Attributes
ITS_SWERR_SYNDROMER0 is a 64-bit register.
This register is part of the ITS_CONFIG_FRAME block.
Field descriptions
| 63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| DEVICE_ID | |||||||||||||||||||||||||||||||
| EVENT_ID | |||||||||||||||||||||||||||||||
DEVICE_ID, bits [63:32]:
The DeviceID for the incoming event that generated the software error.
The reset behavior of this field is:
- On a GIC reset, this field resets to an UNKNOWN value.
EVENT_ID, bits [31:0]:
The EventID for the incoming event that generated the software error.
Unimplemented upper bits are UNKNOWN.
The reset behavior of this field is:
- On a GIC reset, this field resets to an UNKNOWN value.
Access Instructions
Accesses to this register use the following encodings:
Accessible at offset 0x0248 from ITS_CONFIG_FRAME
- When ITS_SWERR_STATUSR.V == '1' and ITS_SWERR_STATUSR.S0V == '1', accesses to this register are RO.
- Otherwise, accesses to this register are UNKNOWN/WI.
()