TRCPDCR
Trace PowerDown Control Register
Requests the system to provide power to the trace unit.
Configuration
This register is present only when FEAT_ETE is implemented and FEAT_TRC_EXT is implemented. Otherwise, direct accesses to TRCPDCR are RES0.
Attributes
TRCPDCR is a 32-bit register.
Field descriptions
Bits [31:4]:
Reserved, RES0.
PU, bit [3]:
Power Up Request.
| PU | Meaning |
|---|---|
| 0b0 |
The system can remove power from the trace unit core power domain, or requests for power to the trace unit core power domain are implemented outside of the trace unit. |
| 0b1 |
The system must provide power to the trace unit core power domain. |
This field is RES0.
Bits [2:0]:
Reserved, RES0.
Accessing TRCPDCR
External debugger accesses to this register are unaffected by the OS Lock.
TRCPDCR can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x310 | TRCPDCR |
Accessible as follows:
- When !IsTraceCorePowered(), accesses to this register generate an error response.
- Otherwise, accesses to this register are RW.