GICR_SETLPIR
Set LPI Pending Register
Generates an LPI by setting the pending state of the specified LPI.
Configuration
A copy of this register is provided for each Redistributor.
Attributes
GICR_SETLPIR is a 64-bit register.
Field descriptions
When GICR_TYPER.DirectLPI == '1':
| 63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RES0 | |||||||||||||||||||||||||||||||
| pINTID | |||||||||||||||||||||||||||||||
Bits [63:32]:
Reserved, RES0.
pINTID, bits [31:0]:
The INTID of the physical LPI to be generated.
The size of this field is IMPLEMENTATION DEFINED, and is specified by the GICD_TYPER.IDbits field. Unimplemented bits are RES0.
When GICR_TYPER.DirectLPI == '0':
| 63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| IMPLEMENTATION DEFINED | |||||||||||||||||||||||||||||||
| IMPLEMENTATION DEFINED | |||||||||||||||||||||||||||||||
IMPLEMENTATION DEFINED, bits [63:0]:
IMPLEMENTATION DEFINED.
Accessing GICR_SETLPIR
When written with a 32-bit write the data is zero-extended to 64 bits.
This register is mandatory in an implementation that supports LPIs and does not include an ITS. The functionality is IMPLEMENTATION DEFINED in an implementation that does include an ITS.
Writes to this register have no effect if either:
- The pINTID field corresponds to an LPI that is already pending.
- The pINTID field corresponds to an unimplemented LPI.
- GICR_CTLR.EnableLPIs == 0.
GICR_SETLPIR can be accessed through the memory-mapped interfaces:
| Component | Frame | Offset | Instance |
|---|---|---|---|
| GIC Redistributor | RD_base | 0x0040 | GICR_SETLPIR |
Accesses to this register are WO.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.