GICD_ISACTIVER<n>, n = 0 - 31

Interrupt Set-Active Registers

Activates the corresponding interrupt. These registers are used when saving and restoring GIC state.

Configuration

These registers are available in all GIC configurations. If GICD_CTLR.DS==0, these registers are Common.

The number of implemented GICD_ISACTIVER<n> registers is (GICD_TYPER.ITLinesNumber+1). Registers are numbered from 0.

GICD_ISACTIVER0 is Banked for each connected PE with GICR_TYPER.Processor_Number < 8.

Accessing GICD_ISACTIVER0 from a PE with GICR_TYPER.Processor_Number > 7 is CONSTRAINED UNPREDICTABLE:

Attributes

GICD_ISACTIVER<n> is a 32-bit register.

Field descriptions

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Set_active_bit31 Set_active_bit30 Set_active_bit29 Set_active_bit28 Set_active_bit27 Set_active_bit26 Set_active_bit25 Set_active_bit24 Set_active_bit23 Set_active_bit22 Set_active_bit21 Set_active_bit20 Set_active_bit19 Set_active_bit18 Set_active_bit17 Set_active_bit16 Set_active_bit15 Set_active_bit14 Set_active_bit13 Set_active_bit12 Set_active_bit11 Set_active_bit10 Set_active_bit9 Set_active_bit8 Set_active_bit7 Set_active_bit6 Set_active_bit5 Set_active_bit4 Set_active_bit3 Set_active_bit2 Set_active_bit1 Set_active_bit0

Set_active_bit<x>, bit [x], for x = 31 to 0:

Adds the active state to interrupt number 32n + x. Reads and writes have the following behavior:

Set_active_bit<x> Meaning
0b0

If read, indicates that the corresponding interrupt is not active, and is not active and pending.

If written, has no effect.

0b1

If read, indicates that the corresponding interrupt is active, or is active and pending.

If written, activates the corresponding interrupt, if the interrupt is not already active. If the interrupt is already active, the write has no effect.

After a write of 1 to this bit, a subsequent read of this bit returns 1.

The reset behavior of this field is:

Additional information

For INTID m, when DIV and MOD are the integer division and modulo operations:

Accessing GICD_ISACTIVER<n>

When affinity routing is enabled for the Security state of an interrupt, bits corresponding to SGIs and PPIs are RAZ/WI, and equivalent functionality for SGIs and PPIs is provided by GICR_ISACTIVER0.

Bits corresponding to unimplemented interrupts are RAZ/WI.

If GICD_CTLR.DS==0, unless the GICD_NSACR<n> registers permit Non-secure software to control Group 0 and Secure Group 1 interrupts, any bits that correspond to Group 0 or Secure Group 1 interrupts are accessible only by Secure accesses and are RAZ/WI to Non-secure accesses.

The bit reads as one if the status of the interrupt is active or active and pending. GICD_ISPENDR<n> and GICD_ICPENDR<n> provide the pending status of the interrupt.

The effect of a write must be visible in finite time. Reading back the written value from either the Set-Active or Clear-Active registers guarantees that a deactivate from a CPU interface Ordered-after the read, will observe the effects of the write on the Active state of the interrupt.

GICD_ISACTIVER<n> can be accessed through the memory-mapped interfaces:

Component Frame Offset Instance
GIC Distributor Dist_base 0x0300 + (4 * n) GICD_ISACTIVER<n>

Accessible as follows: