ARM / OFFLINE REFERENCE

On this page
← Home

SMCR_EL3

SME Control Register (EL3)

This register controls aspects of Streaming SVE that are visible at all Exception levels.

Configuration

This register is present only when FEAT_SME is implemented and EL3 is implemented. Otherwise, direct accesses to SMCR_EL3 are UNDEFINED.

This register has no effect if the PE is not in Streaming SVE mode.

Attributes

SMCR_EL3 is a 64-bit register.

Field descriptions

63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RES0
FA64 EZT0 RES0 RAZ/WI LEN

Bits [63:32]:

Reserved, RES0.

FA64, bit [31] when FEAT_SME_FA64 is implemented:

Controls whether execution of an A64 instruction is considered legal when executed in Streaming SVE mode.

FA64 Meaning
0b0

This control does not cause any instruction to be treated as legal when executed in Streaming SVE mode.

0b1

This control causes all implemented A64 instructions to be treated as legal when executed in Streaming SVE mode .

Arm recommends that portable SME software should not rely on this optional feature, and that operating systems should provide a means to test for compliance with this recommendation.

The reset behavior of this field is:

Otherwise:

Reserved, RES0.

EZT0, bit [30] when FEAT_SME2 is implemented:

Traps execution at all Exception levels of the LDR, LUTI2, LUTI4, MOVT, STR, and ZERO instructions that access the ZT0 register to EL3.

The exception is reported using ESR_EL3.EC value 0x1D, with an ISS code of 0x0000004, at a lower priority than a trap due to PSTATE.SM or PSTATE.ZA.

EZT0 Meaning
0b0

This control causes execution of these instructions at all Exception levels to be trapped.

0b1

This control does not cause execution of any instruction to be trapped.

Changes to this field only affect whether instructions that access ZT0 are trapped. They do not affect the contents of ZT0, which remain valid so long as PSTATE.ZA is 1.

The reset behavior of this field is:

Otherwise:

Reserved, RES0.

Bits [29:9]:

Reserved, RES0.

Bits [8:4]:

Reserved, RAZ/WI.

LEN, bits [3:0]:

Requests an Effective Streaming SVE vector length (SVL) at EL3 of (LEN+1)*128 bits.

The Streaming SVE vector length can be any power of two from 128 bits to 2048 bits inclusive. An implementation can support any subset of the architecturally permitted lengths.

When the PE is in Streaming SVE mode, the Effective SVE vector length (VL) is equal to SVL.

When FEAT_SVE is implemented, and the PE is not in Streaming SVE mode, VL is equal to the Effective Non-streaming SVE vector length. See ZCR_EL3.

For all purposes other than returning the result of a direct read of SMCR_EL3, the PE selects the Effective Streaming SVE vector length by performing checks in the following order:

  1. If the requested length is less than the minimum implemented Streaming SVE vector length, then the Effective length is the minimum implemented Streaming SVE vector length.

  2. Otherwise, the Effective length is the highest supported Streaming SVE vector length that is less than or equal to the requested length.

An indirect read of SMCR_EL3.LEN appears to occur in program order relative to a direct write of the same register, without the need for explicit synchronization.

The reset behavior of this field is:

Access Instructions

Accesses to this register use the following encodings in the System register encoding space:

MRS <Xt>, SMCR_EL3

(op0 = 0b11, op1 = 0b110, CRn = 0b0001, CRm = 0b0010, op2 = 0b110)


if !(IsFeatureImplemented(FEAT_SME) && HaveEL(EL3)) then
    Undefined();
elsif PSTATE.EL == EL0 then
    Undefined();
elsif PSTATE.EL == EL1 then
    Undefined();
elsif PSTATE.EL == EL2 then
    Undefined();
elsif PSTATE.EL == EL3 then
    if CPTR_EL3().ESM == '0' then
        AArch64_SystemAccessTrap(EL3, 0x1D);
    else
        X{64}(t) = SMCR_EL3();
    end;
end;
                

MSR SMCR_EL3, <Xt>

(op0 = 0b11, op1 = 0b110, CRn = 0b0001, CRm = 0b0010, op2 = 0b110)


if !(IsFeatureImplemented(FEAT_SME) && HaveEL(EL3)) then
    Undefined();
elsif PSTATE.EL == EL0 then
    Undefined();
elsif PSTATE.EL == EL1 then
    Undefined();
elsif PSTATE.EL == EL2 then
    Undefined();
elsif PSTATE.EL == EL3 then
    if CPTR_EL3().ESM == '0' then
        AArch64_SystemAccessTrap(EL3, 0x1D);
    else
        SMCR_EL3() = X{64}(t);
    end;
end;
                

Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.

This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.