ARM / OFFLINE REFERENCE

On this page
← Home

HCPTR

Hyp Architectural Feature Trap Register

Controls:

Accesses to this functionality:

  • From Non-secure modes other than Hyp mode are also affected by settings in the CPACR and NSACR.
  • From Hyp mode are also affected by settings in the NSACR.

Exceptions generated by the CPACR and NSACR controls are higher priority than those generated by the HCPTR controls.

Configuration

AArch32 System register HCPTR bits [31:0] are architecturally mapped to AArch64 System register CPTR_EL2[31:0].

This register is present only when FEAT_AA32EL2 is implemented. Otherwise, direct accesses to HCPTR are UNDEFINED.

If EL2 is not implemented, this register is RES0 from EL3.

Attributes

HCPTR is a 32-bit register.

Field descriptions

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TCPAC TAM RES0 TTA RES0 TASE RES0 RES1 TCP11 TCP10 RES1

TCPAC, bit [31]:

Traps Non-secure EL1 MRC and MCR accesses to the CPACR to Hyp mode, reported using EC syndrome value 0x03.

TCPAC Meaning
0b0

This control does not cause any instructions to be trapped.

0b1

Non-secure EL1 accesses to the CPACR are trapped to Hyp mode.

The CPACR is not accessible at EL0.

The reset behavior of this field is:

TAM, bit [30] when FEAT_AMUv1 is implemented:

Trap Activity Monitor access. Traps Non-secure EL1 and EL0 MRC, MCR, MRRC, and MCRR accesses to all Activity Monitors System registers to EL2, reported using EC syndrome values 0x03 and 0x04.

TAM Meaning
0b0

This control does not cause any instructions to be trapped.

0b1

Accesses from Non-secure EL1 and EL0 to Activity Monitors System registers are trapped to Hyp mode.

The reset behavior of this field is:

Otherwise:

Reserved, RES0.

Bits [29:21]:

Reserved, RES0.

TTA, bit [20]:

Traps Non-secure System register MRC, MCR, MRRC, and MCRR accesses to all implemented trace System registers to Hyp mode, reported using EC syndrome values 0x05 and 0x0C.

TTA Meaning
0b0

This control does not cause any instructions to be trapped.

0b1

Any Non-secure System register access to an implemented trace System register is trapped to Hyp mode, unless the access is trapped to EL1 by a CPACR or NSACR control, or the access is from Non-secure EL0 and the definition of the register in the appropriate trace architecture specification indicates that the register is not accessible from EL0. A trapped instruction generates:

  • A Hyp Trap exception, if the exception is taken from Non-secure EL0 or EL1.
  • An Undefined Instruction exception taken to Hyp mode, if the exception is taken from Hyp mode.

If the implementation does not include a trace unit, or does not include a System register interface to the trace unit registers, it is IMPLEMENTATION DEFINED whether this bit:

If EL3 is implemented and is using AArch32, and the value of NSACR.NSTRCDIS is 1, in Non-secure state this field behaves as RAO/WI, regardless of its actual value.

  • FEAT_ETMv4 and FEAT_ETE do not permit EL0 to access the trace System registers. EL0 accesses to the trace System registers are UNDEFINED. A resulting Undefined Instruction exception is higher priority than an HCPTR.TTA Hyp Trap exception.
  • The Arm architecture does not provide traps on trace register accesses through the optional memory-mapped debug interface.

System register accesses to the trace System registers can have side-effects. When a System register access is trapped, any side-effects that are normally associated with the access do not occur before the exception is taken.

The reset behavior of this field is:

Bits [19:16]:

Reserved, RES0.

TASE, bit [15]:

Traps Non-secure execution of Advanced SIMD instructions to Hyp mode, reported using EC syndrome value 0x07, when the value of HCPTR.TCP10 is 0.

TASE Meaning
0b0

This control does not cause any instructions to be trapped.

0b1

When the value of HCPTR.TCP10 is 0, any attempt to execute an Advanced SIMD instruction in Non-secure state is trapped to Hyp mode, unless it is trapped to EL1 by a CPACR or NSACR control. A trapped instruction generates:

  • A Hyp Trap exception, if the exception is taken from Non-secure EL0 or EL1.
  • An Undefined Instruction exception taken to Hyp mode, if the exception is taken from Hyp mode.

When the value of HCPTR.TCP10 is 1, the value of this field is ignored.

If the implementation does not include Advanced SIMD and floating-point functionality, this field is RES1.

Otherwise, it is IMPLEMENTATION DEFINED whether this field is implemented as a RW field. If it is not implemented as a RW field, then it is RAZ/WI.

If EL3 is implemented and is using AArch32, and the value of NSACR.NSASEDIS is 1, in Non-secure state this field behaves as RAO/WI, regardless of its actual value. This applies even if the field is implemented as RAZ/WI.

For the list of instructions affected by this field, see 'Controls of Advanced SIMD operation that do not apply to floating-point operation'.

The reset behavior of this field is:

Bit [14]:

Reserved, RES0.

Bits [13:12]:

Reserved, RES1.

TCP11, bit [11] when FEAT_FP is implemented and FEAT_AdvSIMD is implemented:

The value of this field is ignored. If this field is programmed with a different value to the TCP10 bit then this field is UNKNOWN on a direct read of the HCPTR.

If the implementation does not include Advanced SIMD and floating-point functionality, this field is RES1.

If EL3 is implemented and is using AArch32, and the value of NSACR.cp10 is 0, in Non-secure state this field behaves as RAO/WI, regardless of its actual value.

The reset behavior of this field is:

Accessing this field has the following behavior:

Otherwise:

Reserved, RES1.

TCP10, bit [10] when FEAT_FP is implemented and FEAT_AdvSIMD is implemented:

Trap Non-secure accesses to Advanced SIMD and floating-point functionality to Hyp mode, reported using EC syndrome value 0x07:

TCP10 Meaning
0b0

This control does not cause any instructions to be trapped.

0b1

Any attempted access to Advanced SIMD and floating-point functionality from Non-secure state is trapped to Hyp mode, unless it is trapped to EL1 by a CPACR or NSACR control. A trapped instruction generates:

  • A Hyp Trap exception, if the exception is taken from Non-secure EL0 or EL1.
  • An Undefined Instruction exception taken to Hyp mode, if the exception is taken from Hyp mode.

The Advanced SIMD and floating-point features controlled by these fields are:

If the implementation does not include Advanced SIMD and floating-point functionality, this field is RES1.

If EL3 is implemented and is using AArch32, and the value of NSACR.cp10 is 0, in Non-secure state this field behaves as RAO/WI, regardless of its actual value.

The reset behavior of this field is:

Accessing this field has the following behavior:

Otherwise:

Reserved, RES1.

Bits [9:0]:

Reserved, RES1.

Access Instructions

Accesses to this register use the following encodings in the System register encoding space:

MRC{<c>}{<q>} <coproc>, {#}<opc1>, <Rt>, <CRn>, <CRm>{, {#}<opc2>}

(coproc = 0b1111, opc1 = 0b100, CRn = 0b0001, CRm = 0b0001, opc2 = 0b010)


if !IsFeatureImplemented(FEAT_AA32EL2) then
    Undefined();
elsif HaveEL(EL3) && PSTATE.EL == EL2 && EL3SDDUndefPriority() && IsFeatureImplemented(FEAT_AA64EL3) && !ELUsingAArch32(EL3) && CPTR_EL3().TCPAC == '1' then
    Undefined();
elsif PSTATE.EL == EL0 then
    Undefined();
elsif PSTATE.EL == EL1 then
    if EL2Enabled() && IsFeatureImplemented(FEAT_AA64EL2) && !ELUsingAArch32(EL2) && HSTR_EL2().T1 == '1' then
        AArch64_AArch32SystemAccessTrap(EL2, 0x03);
    elsif EL2Enabled() && IsFeatureImplemented(FEAT_AA32EL2) && ELUsingAArch32(EL2) && HSTR().T1 == '1' then
        AArch32_TakeHypTrapException(0x03);
    else
        Undefined();
    end;
elsif PSTATE.EL == EL2 then
    if HaveEL(EL3) && !ELUsingAArch32(EL3) && CPTR_EL3().TCPAC == '1' then
        if EL3SDDUndef() then
            Undefined();
        else
            AArch64_AArch32SystemAccessTrap(EL3, 0x03);
        end;
    else
        R(t) = HCPTR();
    end;
elsif PSTATE.EL == EL3 then
    if SCR().NS == '0' then
        Undefined();
    else
        R(t) = HCPTR();
    end;
end;
                

MCR{<c>}{<q>} <coproc>, {#}<opc1>, <Rt>, <CRn>, <CRm>{, {#}<opc2>}

(coproc = 0b1111, opc1 = 0b100, CRn = 0b0001, CRm = 0b0001, opc2 = 0b010)


if !IsFeatureImplemented(FEAT_AA32EL2) then
    Undefined();
elsif HaveEL(EL3) && PSTATE.EL == EL2 && EL3SDDUndefPriority() && IsFeatureImplemented(FEAT_AA64EL3) && !ELUsingAArch32(EL3) && CPTR_EL3().TCPAC == '1' then
    Undefined();
elsif PSTATE.EL == EL0 then
    Undefined();
elsif PSTATE.EL == EL1 then
    if EL2Enabled() && IsFeatureImplemented(FEAT_AA64EL2) && !ELUsingAArch32(EL2) && HSTR_EL2().T1 == '1' then
        AArch64_AArch32SystemAccessTrap(EL2, 0x03);
    elsif EL2Enabled() && IsFeatureImplemented(FEAT_AA32EL2) && ELUsingAArch32(EL2) && HSTR().T1 == '1' then
        AArch32_TakeHypTrapException(0x03);
    else
        Undefined();
    end;
elsif PSTATE.EL == EL2 then
    if HaveEL(EL3) && !ELUsingAArch32(EL3) && CPTR_EL3().TCPAC == '1' then
        if EL3SDDUndef() then
            Undefined();
        else
            AArch64_AArch32SystemAccessTrap(EL3, 0x03);
        end;
    else
        HCPTR() = R(t);
    end;
elsif PSTATE.EL == EL3 then
    if SCR().NS == '0' then
        Undefined();
    else
        HCPTR() = R(t);
    end;
end;
                

Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.

This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.