ARM / OFFLINE REFERENCE

On this page
← Home

HLT

Halt instruction

This instruction can generate a Halt Instruction debug event, which causes entry into Debug state.

Within a guarded memory region, while PSTATE.BTYPE != 0b00, an HLT instruction that would cause entry into Debug state will not generate a Branch Target exception and will cause entry into Debug state as normal. For more information, see PSTATE.BTYPE.

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
1 1 0 1 0 1 0 0 0 1 0 imm16 0 0 0 0 0
opc op2 LL

Encoding

HLT #<imm>

Decode

if EDSCR().HDE == '0' || !HaltingAllowed() then
    EndOfDecode(Decode_UNDEF);
elsif IsFeatureImplemented(FEAT_BTI) then
    SetBTypeCompatible(TRUE);
end;

Assembler Symbols

<imm>

Is a 16-bit unsigned immediate, in the range 0 to 65535, encoded in the "imm16" field.

Operation

let is_async : boolean = FALSE;
let fault : FaultRecord = NoFault();
Halt(DebugHalt_HaltInstruction, is_async, fault);

Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.