TRCCNTVR<n>, n = 0 - 3
Trace Counter Value Register <n>
This sets or returns the value of Counter <n>.
Configuration
External register TRCCNTVR<n> bits [31:0] are architecturally mapped to AArch64 System register TRCCNTVR<n>[31:0].
This register is present only when FEAT_ETE is implemented and FEAT_TRC_EXT is implemented. Otherwise, direct accesses to TRCCNTVR<n> are RES0.
Attributes
TRCCNTVR<n> is a 32-bit register.
Field descriptions
Bits [31:16]:
Reserved, RES0.
VALUE, bits [15:0]:
Contains the count value of Counter.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Accessing TRCCNTVR<n>
Must be programmed if TRCRSCTLR<a>.GROUP == 0b0010 and TRCRSCTLR<a>.COUNTERS[n] == 1.
If the trace unit is not in the Idle state it is CONSTRAINED UNPREDICTABLE whether writes to this register are ignored.
Reads from this register might return an UNKNOWN value if the trace unit is not in either of the Idle or Stable states.
TRCCNTVR<n> can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x160 + (4 * n) | TRCCNTVR<n> |
Accessible as follows:
- When OSLockStatus(), or !AllowExternalTraceAccess(addrdesc), or !IsTraceCorePowered(), accesses to this register generate an error response.
- When n >= NUM_TRACE_COUNTERS, accesses to this register are RES0.
- Otherwise, accesses to this register are RW.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.