IRS_PE_CR0
IRS PE Control Register 0
IRS PE Control Register 0.
Configuration
This register is present only when FEAT_GICv5_EXT is implemented. Otherwise, direct accesses to IRS_PE_CR0 are RES0.
The effects of a write to this register are not guaranteed to have completed before IRS_PE_STATUSR.IDLE is 1.
Following a write to this register, IRS_PE_STATUSR.V is updated.
Attributes
IRS_PE_CR0 is a 32-bit register.
This register is part of the IRS_CONFIG_FRAME block.
Field descriptions
The fields in this register provide access to the configuration of the PE specified in the last write to IRS_PE_SELR.
The PE configuration applies to the IRS Domain corresponding to the IRS configuration register frame that this register is accessed in.
Bits [31:1]:
Reserved, RES0.
DPS, bit [0] when IRS_IDR0.ONE_N == '1':
Disable 1ofN PE selection.
| DPS | Meaning |
|---|---|
| 0b0 |
1ofN PE selection is enabled. An interrupt configured to use the 1ofN Routing mode is permitted to select this PE. |
| 0b1 |
1ofN PE selection is disabled. An interrupt configured to use the 1ofN Routing mode is not permitted to select this PE. |
This field determines whether the selected PE is permitted to be selected for 1ofN interrupt delivery.
The reset behavior of this field is:
- On a GIC reset, this field resets to an UNKNOWN value.
Otherwise:
Reserved, RES0.
Access Instructions
Accesses to this register use the following encodings:
Accessible at offset 0x0148 from IRS_CONFIG_FRAME
- When IRS_PE_STATUSR.[V,IDLE] != '11', accesses to this register are UNKNOWN/WI.
- Otherwise, accesses to this register are RW.
()