TRCITEEDCR
Instrumentation Trace Extension External Debug Control Register
Controls instrumentation trace filtering.
Configuration
External register TRCITEEDCR bits [31:0] are architecturally mapped to AArch64 System register TRCITEEDCR[31:0].
This register is present only when FEAT_ETE is implemented, FEAT_TRC_EXT is implemented, and FEAT_ITE is implemented. Otherwise, direct accesses to TRCITEEDCR are RES0.
Attributes
TRCITEEDCR is a 32-bit register.
Field descriptions
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RES0 | RL | S | NS | E3 | E2 | E1 | E0 | ||||||||||||||||||||||||
Bits [31:7]:
Reserved, RES0.
RL, bit [6] when FEAT_RME is implemented:
Instrumentation Trace in Realm state.
| RL | Meaning |
|---|---|
| 0b0 |
Instrumentation trace prohibited in Realm state. |
| 0b1 |
Instrumentation trace permitted in Realm state. |
This field is ignored when SelfHostedTraceEnabled() returns TRUE.
This field is used in conjunction with TRCCONFIGR.ITO and TRCITEEDCR.E<m> to control whether Instrumentation trace is permitted or prohibited in Realm state.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Otherwise:
Reserved, RES0.
S, bit [5] when HaveSecureState():
Instrumentation Trace in Secure state.
| S | Meaning |
|---|---|
| 0b0 |
Instrumentation trace prohibited in Secure state. |
| 0b1 |
Instrumentation trace permitted in Secure state. |
This field is ignored when SelfHostedTraceEnabled() returns TRUE.
When FEAT_RME is not implemented, this field is used in conjunction with TRCCONFIGR.ITO, TRCITEEDCR.E3, and TRCITEEDCR.E<m> to control whether Instrumentation trace is permitted or prohibited in Secure state.
When FEAT_RME is implemented, this field is used in conjunction with TRCCONFIGR.ITO and TRCITEEDCR.E<m> to control whether Instrumentation trace is permitted or prohibited in Secure state.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Otherwise:
Reserved, RES0.
NS, bit [4] when EL3 is implemented or NonSecureOnlyImplementation():
Instrumentation Trace in Non-secure state.
| NS | Meaning |
|---|---|
| 0b0 |
Instrumentation trace prohibited in Non-secure state. |
| 0b1 |
Instrumentation trace permitted in Non-secure state. |
This field is ignored when SelfHostedTraceEnabled() returns TRUE.
This field is used in conjunction with TRCCONFIGR.ITO and TRCITEEDCR.E<m> to control whether Instrumentation trace is permitted or prohibited in Non-secure state.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Otherwise:
Reserved, RES0.
E3, bit [3] when EL3 is implemented:
Instrumentation Trace Enable at EL3.
| E3 | Meaning |
|---|---|
| 0b0 |
Instrumentation trace prohibited at EL3. |
| 0b1 |
Instrumentation trace permitted at EL3. |
This field is ignored when SelfHostedTraceEnabled() returns TRUE.
When FEAT_RME is not implemented, TRCITEEDCR.E3 is used in conjunction with TRCCONFIGR.ITO and TRCITEEDCR.S to control whether Instrumentation trace is permitted or prohibited at EL3.
When FEAT_RME is implemented, TRCITEEDCR.E3 is used in conjunction with TRCCONFIGR.ITO to control whether Instrumentation trace is permitted or prohibited at EL3.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Otherwise:
Reserved, RES0.
E<m>, bit [m], for m = 2 to 0:
Instrumentation Trace Enable at EL<m>.
| E<m> | Meaning |
|---|---|
| 0b0 |
Instrumentation trace prohibited at EL<m>. |
| 0b1 |
Instrumentation trace permitted at EL<m>. |
This field is ignored when SelfHostedTraceEnabled() returns TRUE.
This bit is used in conjunction with TRCCONFIGR.ITO, TRCITEEDCR.NS, TRCITEEDCR.S, and TRCITEEDCR.RL to control whether Instrumentation trace is permitted or prohibited at EL<m> in the specified Security states.
TRCITEEDCR.E<2> is RES0 if EL2 is not implemented in any Security states.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Accessing TRCITEEDCR
If the trace unit is not in the Idle state it is CONSTRAINED UNPREDICTABLE whether writes to this register are ignored.
TRCITEEDCR can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x048 | TRCITEEDCR |
Accessible as follows:
- When OSLockStatus(), or !AllowExternalTraceAccess(addrdesc), or !IsTraceCorePowered(), accesses to this register generate an error response.
- Otherwise, accesses to this register are RW.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.