TRCCNTRLDVR<n>, n = 0 - 3
Trace Counter Reload Value Register <n>
This sets or returns the reload count value for Counter <n>.
Configuration
External register TRCCNTRLDVR<n> bits [31:0] are architecturally mapped to AArch64 System register TRCCNTRLDVR<n>[31:0].
This register is present only when FEAT_ETE is implemented and FEAT_TRC_EXT is implemented. Otherwise, direct accesses to TRCCNTRLDVR<n> are RES0.
Attributes
TRCCNTRLDVR<n> is a 32-bit register.
Field descriptions
Bits [31:16]:
Reserved, RES0.
VALUE, bits [15:0]:
Contains the reload value for Counter <n>. When a reload event occurs for Counter <n> then the trace unit copies the VALUE<n> field into Counter <n>.
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Accessing TRCCNTRLDVR<n>
Must be programmed if TRCRSCTLR<a>.GROUP == 0b0010 and TRCRSCTLR<a>.COUNTERS[n] == 1.
If the trace unit is not in the Idle state it is CONSTRAINED UNPREDICTABLE whether writes to this register are ignored.
TRCCNTRLDVR<n> can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x140 + (4 * n) | TRCCNTRLDVR<n> |
Accessible as follows:
- When OSLockStatus(), or !AllowExternalTraceAccess(addrdesc), or !IsTraceCorePowered(), accesses to this register generate an error response.
- When n >= NUM_TRACE_COUNTERS, accesses to this register are RES0.
- Otherwise, accesses to this register are RW.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.