ARM / OFFLINE REFERENCE

On this page
← Home

CTITRIGINSTATUS

CTI Trigger In Status register

Provides the status of the trigger inputs.

Configuration

CTITRIGINSTATUS is in the Debug power domain.

Attributes

CTITRIGINSTATUS is a 32-bit register.

Field descriptions

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TRIN31 TRIN30 TRIN29 TRIN28 TRIN27 TRIN26 TRIN25 TRIN24 TRIN23 TRIN22 TRIN21 TRIN20 TRIN19 TRIN18 TRIN17 TRIN16 TRIN15 TRIN14 TRIN13 TRIN12 TRIN11 TRIN10 TRIN9 TRIN8 TRIN7 TRIN6 TRIN5 TRIN4 TRIN3 TRIN2 TRIN1 TRIN0

TRIN<n>, bit [n], for n = 31 to 0:

Trigger input <n> status.

TRIN<n> Meaning
0b0

Input trigger n is inactive.

0b1

Input trigger n is active.

Not implemented and not-connected input triggers are always inactive.

It is IMPLEMENTATION DEFINED whether an input trigger that does not support multicycle events can be observed as active.

Accessing this field has the following behavior:

Accessing CTITRIGINSTATUS

CTITRIGINSTATUS can be accessed through the external debug interface:

Component Offset Instance
CTI 0x130 CTITRIGINSTATUS

Accesses to this register are RO.