CTITRIGINSTATUS
CTI Trigger In Status register
Provides the status of the trigger inputs.
Configuration
CTITRIGINSTATUS is in the Debug power domain.
Attributes
CTITRIGINSTATUS is a 32-bit register.
Field descriptions
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TRIN31 | TRIN30 | TRIN29 | TRIN28 | TRIN27 | TRIN26 | TRIN25 | TRIN24 | TRIN23 | TRIN22 | TRIN21 | TRIN20 | TRIN19 | TRIN18 | TRIN17 | TRIN16 | TRIN15 | TRIN14 | TRIN13 | TRIN12 | TRIN11 | TRIN10 | TRIN9 | TRIN8 | TRIN7 | TRIN6 | TRIN5 | TRIN4 | TRIN3 | TRIN2 | TRIN1 | TRIN0 |
TRIN<n>, bit [n], for n = 31 to 0:
Trigger input <n> status.
| TRIN<n> | Meaning |
|---|---|
| 0b0 |
Input trigger n is inactive. |
| 0b1 |
Input trigger n is active. |
Not implemented and not-connected input triggers are always inactive.
It is IMPLEMENTATION DEFINED whether an input trigger that does not support multicycle events can be observed as active.
Accessing this field has the following behavior:
- When n >= UInt(CTIDEVID.NUMTRIG), access to this field is RAZ/WI.
- Otherwise, access to this field is RO.
Accessing CTITRIGINSTATUS
CTITRIGINSTATUS can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| CTI | 0x130 | CTITRIGINSTATUS |
Accesses to this register are RO.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.