ARM / OFFLINE REFERENCE

On this page
← Home

CTIOUTEN<n>, n = 0 - 31

CTI Input Channel to Output Trigger Enable registers

Defines which input channels generate output trigger n.

Configuration

CTIOUTEN<n> is in the Debug power domain.

If output trigger n is not implemented or not connected, CTIOUTEN<n> is RES0.

Attributes

CTIOUTEN<n> is a 32-bit register.

Field descriptions

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
OUTEN31 OUTEN30 OUTEN29 OUTEN28 OUTEN27 OUTEN26 OUTEN25 OUTEN24 OUTEN23 OUTEN22 OUTEN21 OUTEN20 OUTEN19 OUTEN18 OUTEN17 OUTEN16 OUTEN15 OUTEN14 OUTEN13 OUTEN12 OUTEN11 OUTEN10 OUTEN9 OUTEN8 OUTEN7 OUTEN6 OUTEN5 OUTEN4 OUTEN3 OUTEN2 OUTEN1 OUTEN0

OUTEN<x>, bit [x], for x = 31 to 0:

Input channel <x> to output trigger <n> enable.

OUTEN<x> Meaning
0b0

An event on input channel <x> will not cause output trigger <n> to be asserted.

0b1

An event on input channel <x> will cause output trigger <n> to be asserted.

The reset behavior of this field is:

Accessing this field has the following behavior:

Accessing CTIOUTEN<n>

CTIOUTEN<n> can be accessed through the external debug interface:

Component Offset Instance
CTI 0x0A0 + (4 * n) CTIOUTEN<n>

Accessible as follows: