ARM / OFFLINE REFERENCE

On this page
← Home

CTIINEN<n>, n = 0 - 31

CTI Input Trigger to Output Channel Enable registers

Enables the signaling of an event on output channels when input trigger event n is received by the CTI.

Configuration

CTIINEN<n> is in the Debug power domain.

If input trigger n is not implemented or not connected, CTIINEN<n> is RES0.

Attributes

CTIINEN<n> is a 32-bit register.

Field descriptions

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
INEN31 INEN30 INEN29 INEN28 INEN27 INEN26 INEN25 INEN24 INEN23 INEN22 INEN21 INEN20 INEN19 INEN18 INEN17 INEN16 INEN15 INEN14 INEN13 INEN12 INEN11 INEN10 INEN9 INEN8 INEN7 INEN6 INEN5 INEN4 INEN3 INEN2 INEN1 INEN0

INEN<x>, bit [x], for x = 31 to 0:

Input trigger <n> to output channel <x> enable.

INEN<x> Meaning
0b0

Input trigger <n> will not generate an event on output channel <x>.

0b1

Input trigger <n> will generate an event on output channel <x>.

The reset behavior of this field is:

Accessing this field has the following behavior:

Accessing CTIINEN<n>

CTIINEN<n> can be accessed through the external debug interface:

Component Offset Instance
CTI 0x020 + (4 * n) CTIINEN<n>

Accessible as follows: