ARM / OFFLINE REFERENCE

On this page
← Home

ICC_IDR0_EL1

Interrupt Controller ID Register 0

Contains information about features implemented by the GICv5 CPU interface.

Configuration

This register is present only when FEAT_GCIE is implemented and FEAT_AA64 is implemented. Otherwise, direct accesses to ICC_IDR0_EL1 are UNDEFINED.

Attributes

ICC_IDR0_EL1 is a 64-bit register.

Field descriptions

63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RES0
RES0 GCIE_LEGACY PRI_BITS ID_BITS

Bits [63:12]:

Reserved, RES0.

GCIE_LEGACY, bits [11:8]:

Indicates support for legacy GICv3.3 virtual CPU interface.

The value of this field is an IMPLEMENTATION DEFINED choice of:

GCIE_LEGACY Meaning
0b0000

Legacy GICv3.3 virtual CPU interface is not implemented

0b0001

Legacy GICv3.3 virtual CPU interface is implemented

FEAT_GCIE_LEGACY extension implements the functionality identified by the value 0b0001.

Access to this field is RO.

PRI_BITS, bits [7:4]:

The number of priority bits implemented, minus one.

The number of supported priority bits is 5.

Other values are reserved.

Reads as 0b0100.

Access to this field is RO.

ID_BITS, bits [3:0]:

Identifier bits.

The number of interrupt identifier bits supported.

The value of this field is an IMPLEMENTATION DEFINED choice of:

ID_BITS Meaning
0b0000

16 bits

0b0001

24 bits

Access to this field is RO.

Access Instructions

This register is Read-only.

Accesses to this register use the following encodings in the System register encoding space:

MRS <Xt>, ICC_IDR0_EL1

(op0 = 0b11, op1 = 0b000, CRn = 0b1100, CRm = 0b1010, op2 = 0b010)


if !(IsFeatureImplemented(FEAT_GCIE) && IsFeatureImplemented(FEAT_AA64)) then
    Undefined();
elsif PSTATE.EL == EL0 then
    Undefined();
elsif PSTATE.EL == EL1 then
    if EL2Enabled() && HCR_EL2().IMO == '1' && IsFeatureImplemented(FEAT_GCIE_LEGACY) && ICH_VCTLR_EL2().V3 == '1' then
        Undefined();
    elsif EL2Enabled() && ICH_HFGRTR_EL2().ICC_IDRn_EL1 == '0' then
        AArch64_SystemAccessTrap(EL2, 0x18);
    else
        X{64}(t) = ICC_IDR0_EL1();
    end;
elsif PSTATE.EL == EL2 then
    X{64}(t) = ICC_IDR0_EL1();
elsif PSTATE.EL == EL3 then
    X{64}(t) = ICC_IDR0_EL1();
end;
                

Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.