ARM / OFFLINE REFERENCE

On this page
← Home

FMAXNM (scalar)

Floating-point maximum number (scalar)

This instruction compares the first and second source SIMD&FP register values, and writes the larger of the two floating-point values to the destination SIMD&FP register.

The behavior is as follows:

This instruction can generate a floating-point exception. Depending on the settings in FPCR, the exception results in either a flag being set in FPSR or a synchronous exception being generated. For more information, see Floating-point exceptions and exception traps.

Depending on the settings in the CPACR_EL1, CPTR_EL2, and CPTR_EL3 registers, and the current Security state and Exception level, an attempt to execute the instruction might be trapped.

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 0 1 1 1 1 0 ftype 1 Rm 0 1 1 0 1 0 Rn Rd
M S op

Half-precision encoding
(FEAT_FP16)

(ftype == 11)

FMAXNM <Hd>, <Hn>, <Hm>

Single-precision encoding
(FEAT_FP)

(ftype == 00)

FMAXNM <Sd>, <Sn>, <Sm>

Double-precision encoding
(FEAT_FP)

(ftype == 01)

FMAXNM <Dd>, <Dn>, <Dm>

Decode (all encodings)

if !IsFeatureImplemented(FEAT_FP) then EndOfDecode(Decode_UNDEF); end;
if ftype == '10' then EndOfDecode(Decode_UNDEF); end;
if ftype == '11' && !IsFeatureImplemented(FEAT_FP16) then EndOfDecode(Decode_UNDEF); end;

let d : integer{} = UInt(Rd);
let n : integer{} = UInt(Rn);
let m : integer{} = UInt(Rm);

let esize : integer{} = 8 << UInt(ftype XOR '10');

Assembler Symbols

<Hd>

Is the 16-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Hn>

Is the 16-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Hm>

Is the 16-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<Sd>

Is the 32-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Sn>

Is the 32-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Sm>

Is the 32-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<Dd>

Is the 64-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Dn>

Is the 64-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Dm>

Is the 64-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

Operation

AArch64_CheckFPEnabled();
let operand1 : bits(esize) = V{}(n);
let operand2 : bits(esize) = V{}(m);

var result : bits(128) = if IsMerging(FPCR()) then V{128}(n) else Zeros{128};

result[0+:esize] = FPMaxNum{esize}(operand1, operand2, FPCR());

V{128}(d) = result;

Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.

This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.