Floating-point divide (scalar)

This instruction divides the floating-point value of the first source SIMD&FP register by the floating-point value of the second source SIMD&FP register, and writes the result to the destination SIMD&FP register.

This instruction can generate a floating-point exception. Depending on the settings in FPCR, the exception results in either a flag being set in FPSR or a synchronous exception being generated. For more information, see Floating-point exceptions and exception traps.

Depending on the settings in the CPACR_EL1, CPTR_EL2, and CPTR_EL3 registers, and the current Security state and Exception level, an attempt to execute the instruction might be trapped.

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 0 1 1 1 1 0 ftype 1 Rm 0 0 0 1 1 0 Rn Rd
M S opcode

Half-precision encoding
(FEAT_FP16)

(ftype == 11)

FDIV <Hd>, <Hn>, <Hm>

Single-precision encoding
(FEAT_FP)

(ftype == 00)

FDIV <Sd>, <Sn>, <Sm>

Double-precision encoding
(FEAT_FP)

(ftype == 01)

FDIV <Dd>, <Dn>, <Dm>

Decode (all encodings)

if !IsFeatureImplemented(FEAT_FP) then EndOfDecode(Decode_UNDEF); end;
if ftype == '10' then EndOfDecode(Decode_UNDEF); end;
if ftype == '11' && !IsFeatureImplemented(FEAT_FP16) then EndOfDecode(Decode_UNDEF); end;

let d : integer{} = UInt(Rd);
let n : integer{} = UInt(Rn);
let m : integer{} = UInt(Rm);

let esize : integer{} = 8 << UInt(ftype XOR '10');

Assembler Symbols

<Hd>

Is the 16-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Hn>

Is the 16-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Hm>

Is the 16-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<Sd>

Is the 32-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Sn>

Is the 32-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Sm>

Is the 32-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<Dd>

Is the 64-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Dn>

Is the 64-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Dm>

Is the 64-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

Operation

AArch64_CheckFPEnabled();
let operand1 : bits(esize) = V{}(n);
let operand2 : bits(esize) = V{}(m);

var result : bits(128) = if IsMerging(FPCR()) then V{128}(n) else Zeros{128};

result[0+:esize] = FPDiv{esize}(operand1, operand2, FPCR());

V{128}(d) = result;