TRCRSR
Trace Resources Status Register
Use this to set, or read, the status of the resources.
Configuration
External register TRCRSR bits [31:0] are architecturally mapped to AArch64 System register TRCRSR[31:0].
This register is present only when FEAT_ETE is implemented and FEAT_TRC_EXT is implemented. Otherwise, direct accesses to TRCRSR are RES0.
Attributes
TRCRSR is a 32-bit register.
Field descriptions
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RES0 | TA | EVENT[3] | EVENT[2] | EVENT[1] | EVENT[0] | RES0 | EXTIN[3] | EXTIN[2] | EXTIN[1] | EXTIN[0] | |||||||||||||||||||||
Bits [31:13]:
Reserved, RES0.
TA, bit [12]:
Tracing active.
| TA | Meaning |
|---|---|
| 0b0 |
Tracing is not active. |
| 0b1 |
Tracing is active. |
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
EVENT[<m>], bit [m+8], for m = 3 to 0:
Untraced status of ETEEvents.
| EVENT[<m>] | Meaning |
|---|---|
| 0b0 |
An ETEEvent <m> has not occurred. |
| 0b1 |
An ETEEvent <m> has occurred while the resources were in the Paused state. |
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Accessing this field has the following behavior:
- When TRCIDR4.NUMRSPAIR == '0000', access to this field is RES0 .
-
Access to this field is
RES0
if all the following are true:
- TRCIDR4.NUMRSPAIR != '0000'.
- m > UInt(TRCIDR0.NUMEVENT).
- Otherwise, access to this field is RW.
Bits [7:4]:
Reserved, RES0.
EXTIN[<m>], bit [m], for m = 3 to 0:
The sticky status of the External Input Selectors.
| EXTIN[<m>] | Meaning |
|---|---|
| 0b0 |
An event selected by External Input Selector <m> has not occurred. |
| 0b1 |
At least one event selected by External Input Selector <m> has occurred while the resources were in the Paused state. |
The reset behavior of this field is:
- On a Trace unit reset, this field resets to an architecturally UNKNOWN value.
Accessing this field has the following behavior:
- When m >= UInt(TRCIDR5.NUMEXTINSEL), access to this field is RES0 .
- Otherwise, access to this field is RW.
Accessing TRCRSR
Must always be programmed.
If the trace unit is not in the Idle state it is CONSTRAINED UNPREDICTABLE whether writes to this register are ignored.
Reads from this register might return an UNKNOWN value if the trace unit is not in either of the Idle or Stable states.
TRCRSR can be accessed through the external debug interface:
| Component | Offset | Instance |
|---|---|---|
| ETE | 0x028 | TRCRSR |
Accessible as follows:
- When OSLockStatus(), or !AllowExternalTraceAccess(addrdesc), or !IsTraceCorePowered(), accesses to this register generate an error response.
- Otherwise, accesses to this register are RW.
Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.
This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.